product

Air Cooled Type Water Chiller

a/am-series

Series

  • A-series
    (2A ~ 10A)

  • A-series
    (15A ~ 50A)

  • AM Series
    (Including outdoor Unit)

Characteristic

  • Possible to check the conditions of Chiller through LCD Screens
  • Wide temperature Control option (-15 degree~+80 degree) option
  • After blackout, it comes back automatically
  • Option for cold and hot water option
  • Easily movable with attached wheels
  • Easily free up installation space cooling tower is unnecessary
  • Possible to check the conditions of Chiller through LCD Screens
  • Wide temperature Control option (-15 degree~+80 degree) option
  • After blackout, it comes back automatically
  • Option for cold and hot water option
  • Easily movable with attached wheels
  • Minimize noisy by seperating condenser and indoor system, it prevents degradation of cooling ability caused by increasing the room temperature
  • Preventing degradation of cooling ability when indoor temperature is above 27 degrees, the environment can be comfortable by separating and installing Cooler outside
  • For the place of no Ventilation, Less production, and higher heat, AM series is suitable
  • * This item is needed outdoor unit facilities(including product)when it using

Flow Diagram

Ref. Gas Line Water Line
  • ACompressor
  • BOil Separator
  • CAircooled condenser
  • DReceiver tank
  • EFilter drier
  • FSight glass
  • GSolenoid Valve
  • HExpansion valve
  • IAccumulator
  • JWater tank & Senser
  • KEvaporator
  • LCity Water Supply
  • MWater Return
  • NWater Supply
  • OWater Gauge
  • PBy-pass valve
  • QCirculation pump
  • RDrain Valve
  • SDigital Pressure
Ref. Gas Line Water Line
  • ACompressor
  • BOil Separator
  • CAircooled condenser
  • DReceiver tank
  • EFilter drier
  • FSight glass
  • GSolenoid Valve
  • HExpansion valve
  • IAccumulator
  • JWater tank & Senser
  • KEvaporator
  • LCity Water Supply
  • MWater Return
  • NWater Supply
  • OWater Gauge
  • PBy-pass valve
  • QCirculation pump
  • RDrain Valve
  • SDigital Pressure

Standard Specification

Item DH-2A DH-3A DH-5A DH-7.5A DH-10A DH-15A DH-20A DH-30A DH-40A DH-50A
Refrigerator Capacity 2 3 5 7.5 10 15 20 30 40 50
Port Size (Inlet/Outlet) 25A(1") 40A(1-1/2") 50A(2")
Cooling Medium Water, D I water, Antifreeze, Distilled water
Refrigerant R-22 / R-404A / R-407C
Weight (kg) 160 200 250 310 410 580 700 900 1,100 1,600
Compressor Output (kW) 1.5 2.25 3.75 5.5 7.5 11.25 15 22.5 30 37.5
Cooling Capacity (at 20℃,Kcal/h) 5,600 8,400 14,000 21,000 28,000 42,000 56,000 84,000 112,000 140,000
Circulation Pump Output (kW) 0.75 1.85 3
Pump Head (M) 35
Pump Flow Rate (L/min) 72 150 300
Display Digital Automatic Temperature Control
Safety Alarm Low water level, High/Low pressure, Sense gas leaking, Overload,
Phase detection, High/Low temperature, Anti freeze, Water flow sensor
Water Tank (L) 35 45 100 100 135 250 350 600 700 700
Dimension 780 x
605 x
1,195"
850 x
665 x
1,395"
1,310 x
760 x
1,470"
1310 x
760 x
1,470"
1,500 x
805 x
1,570"
1,770 x
900 x
1,752"
2,070 x
1,000 x
1,752"
2,930 x
1,000 x
1,803"
3,230 x
1,100 x
1,973"
3,770 x
1,100 x
2,190"
Total Power Consumption 2.5 3.3 4.9 6.8 10.2 15 18 27 37 48
Power (v) AC 1Φ 220V 50/60Hz
AC 3Φ 220/380/440V 50/60Hz
AC 3Φ 220/380/440V 50/60Hz

※ All the details can be changed without any notice with the products developed.
(Option : ±0.1℃ temperature control, Ultralow-temperature Chiller(-80℃), Customized order)

Item DH-2AM DH-3AM DH-5AM DH-7.5AM DH-10AM DH-15AM DH-20AM DH-30AM DH-40AM DH-50AM
Refrigerator Capacity 2 3 5 7.5 10 15 20 30 40 50
Port Size
(Inlet/Outlet)
25A(1") 40A(1-1/2") 50A(2")
Cooling Medium Water, D I water, Antifreeze, Distilled water
Refrigerant R-22 / R-404A / R-407C
Weight(kg) 110 150 250 290 430 530 680 830 930 1,100
Compressor Output (kW) 1.5 2.25 3.75 5.5 7.5 11.25 15 22.5 30 37.5
Cooling Capacity
(at 20℃,Kcal/h)
5,600 8,400 14,000 21,000 28,000 42,000 56,000 84,000 112,000 140,000
Circulation Pump Output (kW) 0.75 1.85 3
Pump Head (M) 35 28
Pump Flow Rate (L/min) 72 150 300
Display Digital Automatic Temperature Control
Safety Alarm Low water level, High/Low pressure, Sense gas leaking, Overload.
Phase detection, High/Low temperature, Anti freeze, Water flow sensor
Water Tank (L) 55 55 110 140 170 250 300 450 550 650
Indoor dimension
(L x W x H)
780 x
605 x
1,085
780 x
605 x
1,085
850 x
665 x
1,275
1,310 x
760 x
1,350
1,310 x
760 x
1,350
1,500 x
800 x
1,450
1,745 x
900 x
1,550
1,980 x
950 x
1,775
1,980 x
985 x
1,775
1,981 x
950 x
1,773
Outdoor dimension
(L x W x H)
700 x
470 x
520
700 x
470 x
990
925 x
855 x
1,023
1,346 x
800 x
712
1,576 x
900 x
810
1,576 x
943 x
910
2,226 x
904 x
910
2,706 x
1,116 x
915
3,297 x
1,082 x
915
3,297 x
1,082 x
915
Total Power Consumption 2.5 3.3 4.9 6.8 10.2 15 18 27 37 48
Power (v) AC 3Φ 220/380/440V 50/60Hz

※ All the details can be changed without any notice with the products developed.
(Option : ±0.1℃ temperature control, Ultralow-temperature Chiller(-80℃), Customized order)

Purpose of Use

  • Processing machinery
  • Wire cutting
  • Injection/
    Extrude molding machine
  • Vaccume/
    Rubber molding machine
  • Roller/Mixer equipment
  • Laser machinery
  • Plating Equipment/
    Grinder
  • Printing machinery
  • Food processing machinery
  • Medical instrument
  • High frequency/
    Ultrasonic equipment
  • Custom made solution